Posts

KD4190 Digital three phase sequence indica

It can be used for indicating the phase sequence and checking the open phase of three phase AC power.

 

Features

  • Can be used frequency range from 40Hz to 60Hz voltage from 100V to 600V of three phase AC power
  • When opening phase, the LED will turn off with buzzing.Timewise arrow and sequence of LED turning on indicate the three AC power phase.
  • No metal parts outside,good insulate capability for safety.
  • Small size and light weight for carrying easily.

 

Measuring Range Frequency :40Hz~60Hz Voltage:100V~600V
Insulation Value ≥50MΩ (1000V)
Withstand Voltage AC2kV   50Hz    1min
Operating Temperature&Humidity -10~+40 degree;   less than85% RH
Dimensions 115mm×70mm×40mm
Weight ≈300g
Send Inquiry
[[[],[],"and"]]
1
Nameyour full name
PhonePhone number
Previous
Next

DER2571B INSULATION RESISTANCE TESTER

It can be used for measuring earth resistance of various of low resistance conductors and also be used for testing earth resistivity and testing earth voltage


Features

– 3 1/2 LCD digital display, big screen for easy reading
– Capability of preventing disturbance from earth voltage, promise normal test without open the circuit .
– If auxiliary earth resistance of potential terminal Rp and of current terminal Rc are as below value:
Rp=50kΩ
Rc=1kΩ (range 0.00~19.99Ω)
Rc=10kΩ (range 20.0~199.9Ω;200~1999Ω)
There is no influence on measuring.
– If earth return circuit is opened, OPEN CIRCUIT is given on LCD .
– Battery supply, low battery indication .

Send Inquiry
[[[],[],"and"]]
1
Nameyour full name
PhonePhone number
Previous
Next

MODEL 3124

Permits a wide range of insulation testing up to 100GΩ at variable test voltage from 1kV to 10kV.

• DC voltage output for recorders.
• Output voltage is shown on the digital display.
• After tests, automatically discharges the charges stored in the circuit under test.
• Operated by rechargeable Nickel-Cadmium batteries

Insulation Resistance

DC Test Voltage 1k – 10kV variable / 1000V
Measuring ranges
(automatic change)
1.6GΩ/100GΩ (autoranging) (1k – 10kV variable)
100MΩ (1000V)
First effective measuring range 0.05 – 50GΩ (1k – 10kV variable)
1 – 100MΩ (1000V)
Accuracy ±10% rdg
Other ranges accuracy ±1% of scale length
Output voltage and set voltage indicate DC 0 – 10kV
±2%rdg±2dgt

General

Power source Ni-Cd rechargeable battery (1.2V) × 8
Dimensions 200(L) × 140(W) × 80(D)mm
Weight 1.5kg approx.
Included Accessories 7082 (Lead for recorder)
7083 (Lead for battery charging)
7084 (Earth and guard leads)
8075 (120V) or 8080 (220V) (Battery charger)
9176 (Carrying case [Hard])
Ni-Cd rechargeable battery × 8
Instruction Manual

 

 

Send Inquiry
[[[],[],"and"]]
1
Nameyour full name
PhonePhone number
Previous
Next

DMG-2671P

Application

It can be used to measure insulation resistance of various electric equipments, transformers, switches, electric motors, cables, and insulating materials.

Features

  • 3 1/2 LCD Digital display for easy reading.
  • It’s portable and easy-to-operate.
  • Low power consumption and powered by a battery. Turn off the supply automatically after about 5 minutes operating time.
  • Provide with battery check function.
  • Three rated output voltages available for one set

Specifications

model 2671P 2671P1
Rated Voltage(V) 250,500,1000 100,250,500
Output Voltage(V) Rated Voltage±10%
Load ≥20MΩ Load ≥10MΩ
Measuring Range & Error (0.1~1999)MΩ

±(5%RDG+2d)

Output Short Circuit Current ≥1mA ≥0.5mA

Insulation Resistance         : ≥50MW (1000V)

Withstand Voltage : AC  3kV  50Hz  1min

Operating Temperature &. Humidity:0℃~+40oC <85%RH

Storage Temperature &. Humidity:-10℃~ +50oC  <90%RH

Power Supply         :9V battery

Power Consumption          : ≤60mA

Dimensions             : 195mm(L)´95mm(W)´40mm(H)

Weight : Approx. 300g

Send Inquiry
[[[],[],"and"]]
1
Nameyour full name
PhonePhone number
Previous
Next

ISOL 5000

This used Chauvin Arnoux ISOL 5000 Insulation tester is in very good condition.
Set of two original safety test leads, user manual and spare fuse are included.
The instrument has been designed for measuring insulating resistance up to 3000 GOhm with testing voltage selectable up to 5kV.
Measurements according standards NFC 15-100 and VDE 413.

Send Inquiry
[[[],[],"and"]]
1
Nameyour full name
PhonePhone number
Previous
Next

DMG2671T Digital Insulation/Continuity Tester

Insulation Resistance:

Rated Voltage 250V;500V;1000V
Open Circuit Voltage Rated Voltage(+20 % – 0 % )
Measuring Range ( 0~19.99) M Ω;(0~199.9)M Ω
Accuracy ±( 5 % RDG+2d)
Short Circuit Current ≥ 1mA

Continuity:

Open Circuit Voltage 4V ~ 7V
Measuring Range ( 0~19.99) Ω       (0~199.9) Ω
Accuracy ±( 5 % RDG+2d)
Short Circuit Current ≥ 200mA

 

Withstand Voltage AC3KV   50Hz   1min
Operating Temperature&Humidity 0℃~40℃; < 85% RH
Power Supply 6×1.5V(R6 or LR6) Battery
Dimensions 190 mm ( L ) × 110 mm ( W ) × 58 mm ( D )
Weight ≈ 0.5kg

 

Send Inquiry
[[[],[],"and"]]
1
Nameyour full name
PhonePhone number
Previous
Next

The Fluke 376

The Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes.

Additionally, the Fluke 376 includes the new iFlex™ flexible current probe, which expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access.

The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter.

Send Inquiry
[[[],[],"and"]]
1
Nameyour full name
PhonePhone number
Previous
Next

Fluke 87V Industrial Multimeter

Built like a brick, the most trustworthy meter I’ve ever worked with my last 30 years in both professional (radar installations etc.) and private (amateur radio stuff etc.) troubleshooting electric and electronic devices…

– Martin from Hamburg, Germany.

Designed to Identify Complex Signal Problems Fast

When productivity is on the line and you need to solve problems fast, the Fluke 87V delivers the accuracy and advanced troubleshooting capabilities you need. Designed specifically to handle complex signals, the 87V industrial multimeter, allows you to gain productivity by taking the guesswork out of drive system troubleshooting even in loud, high energy, and high altitude locations.

o Accurate frequency measurements on adjustable speed drives (ASD) due to Fluke-designed low-pass filter
o Built-in thermometer allows temperature measurements without a separate thermometer
o Peak Min/Max allows capture of intermittents as fast 250 µS
o Dual display resolution – 6000 or 20,000 counts – lets you see small changes in displayed readings
o CAT III 1000V, CAT IV 600V safety rated
o Designed and built in the U.S.A.
o Lifetime warranty

The Fluke 87V – Just One of Fluke’s Trusted Tools

Fluke builds the most trusted tools in the world and that means more than just the Fluke 87V.
If you work with HVAC equipment, need a small meter for small spaces or work in the electrical installer’s and repairman’s world, check out the full family of Fluke digital multimeters

o Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
o Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
o Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
o Large digit display with bright, two-level backlight makes the 87V significantly easier to read than older models
o True RMS AC voltage and current for accurate measurements on non linear signals
o Selectable filter for accurate voltage and frequency measurements on motor drives
o 0.05% DC accuracy
o 6000 counts, 3-3/4 digits
o 4-1/2 digit mode for precise measurements (20,000 counts)
o Measure up to 1000 VAC and DC
o Measure up to 10 A, 20 A for up to 30 seconds
o Built in thermometer lets you carry one less tool (TC probe included)
o Frequency to 200 kHz and % duty cycle
o Resistance, continuity and diode test
o 10,000 µF capacitance range for components and motor caps
o Min/Max-Average recording with Min/Max Alert to capture variations automatically
o Peak capture to record transients as fast as 250 µs
o Relative mode to remove test lead interference from low ohms measurements
o Auto and manual ranging for maximum flexibility
o Touch Hold to capture stable readings avoiding noisy signals
o Large display digits and two-level bright white backlight for increased visibility
o Analog bargraph for fast changing or unstable signals
o Input Alert provides audible warning against wrong use of input jacks
o Improved selectable sleep mode for long battery life
o Access door for fast battery changes without breaking the calibration seal
o “Classic” design with new removable holster with built in test lead and probe storage
o Lifetime warranty

Electrical safety

 

 

All inputs are updated to the 3rd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
Until now, there hasn’t been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals.

Think of the potential productivity you’ll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.

o Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
o Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
o Measure AC current with an optional current clamp accessory
o Compare reading from the 87V with the display on the ASD
o Special shielding blocks high frequency, high-energy noise generated by large drive systems

Send Inquiry
[[[],[],"and"]]
1
Nameyour full name
PhonePhone number
Previous
Next

Fluke 196C ScopeMeter Oscilloscope

For demanding applications the Fluke 196C ScopeMeter series high-performance oscilloscope offers specifications usually found on top-end bench instruments. The Fluke 196C ScopeMeter has a dual input, 100 MHz bandwidth and 1 GS/s real-time sample rate. The instrument also features a high resolution color display and a high waveform resolution of 3000 data points per channel.

The Fluke 196C ScopeMeter features Connect-and-View automatic triggering and a full range of manual trigger modes plus external triggering options, frequency spectrum analysis using Fast Fourier Transform and digital persistence for analyzing complex dynamic waveforms as you would with an analog scope. The fast display update rate is ideal for seeing dynamic behavior instantaneously.

The Fluke 196C ScopeMeter always memorizes the last 100 screens (no user setup required). When an anomaly occurs on screen, the REPLAY button can be pressed to review the full screen sequence over and over.
The instrument also has a 5000 count DMM and paperless recorder built-in. The Fluke 196C runs for four hours on a rechargeable NiMH battery pack.

The Fluke 196C ScopeMeter ships complete with:

• BC190 battery charger/line voltage adapter
• BP190 NiMH battery pack
• TL75 hard point test lead set
• VPS210-G voltage probe – grey
• VPS210-R voltage probe – red
• STL120 shielded test lead set
• User’s manual (CD-ROM)
• Getting started guide

The Fluke 196C ScopeMeter is also available in a kit (SCC190) which includes:
• C190 protective hard shell carrying case
• OC4USB optically isolated USB cable
• SW90W FlukeView software for Windows

Send Inquiry
[[[],[],"and"]]
1
Nameyour full name
PhonePhone number
Previous
Next

Quick identification of PD activities in switchgear and cable accessories

The BAUR PD-SGS handheld online PD detector is used to conduct rapid initial tests for PD activities on live switchgear. Potential weak points are immediately signalled acoustically and numerically.

• Initial rapid condition evaluation of switchgear and cable accessories during mains operation
• Ideal for quick checks of MV and HV switchgear
• Two integrated sensors:
TEV sensor records PD on the surfaces of switchgears
Acoustic sensor records PD inside switchgears
• Greater safety for test personnel – switchgear tested for safety risks before starting work

Send Inquiry
[[[],[],"and"]]
1
Nameyour full name
PhonePhone number
Previous
Next